906R
CURTIS
9030339000
Specifications
Manufacturer: CURTIS
Model: 906R24BNBAO
Voltage Options (Volts): 24V
Operating voltage: +/–25% of nominal voltage
Display: 10-digit, LED
Operating temperature: –40°C to +85°C
Storage temperature: –50°C to +90°C
Shock & Vibration: Meets SAE J 1378
Features include:
All principal circuits are integrated in a single chip for long-life reliability.
A 10-bar LED displays the state-of-charge successively, bar by bar, from full to empty.
At 70% depth of discharge, a flashing LED signals an “energy reserve” alert.
At 80%, alternately flashing LEDs provides an “empty” status warning.
Model 906R24BNBAO is compact and easily installed in panel cutouts as small as Ø 52.4 mm, with as little as 35 mm behind panel clearance needed.
Recognizes improperly charged battery.
Keyswitch activated LED display (state-of-charge is monitored as long as 906 is connected to battery).
Memory allows gauge to recall state-of-charge whenever battery is disconnected.
Three possible reset methods:
Open Circuit Reset (OCR): Upon reconnection of a battery the gauge will reset if it measures 2.09 volts/ cell or higher (example “B” profile) (for units with memory option).
High Voltage Reset (HVR): Gauge must measure >2.35 volts per cell for 6 continuous minutes during charging (example “B” profile).
Charge Tracking Reset (CTR): Display tracks charge level during opportunity charging (requires gauge to be connected to battery when charging).
Specifications
Manufacturer: CURTIS
Model: 906R24BNBAO
Voltage Options (Volts): 24V
Operating voltage: +/–25% of nominal voltage
Display: 10-digit, LED
Operating temperature: –40°C to +85°C
Storage temperature: –50°C to +90°C
Shock & Vibration: Meets SAE J 1378
Features include:
All principal circuits are integrated in a single chip for long-life reliability.
A 10-bar LED displays the state-of-charge successively, bar by bar, from full to empty.
At 70% depth of discharge, a flashing LED signals an “energy reserve” alert.
At 80%, alternately flashing LEDs provides an “empty” status warning.
Model 906R24BNBAO is compact and easily installed in panel cutouts as small as Ø 52.4 mm, with as little as 35 mm behind panel clearance needed.
Recognizes improperly charged battery.
Keyswitch activated LED display (state-of-charge is monitored as long as 906 is connected to battery).
Memory allows gauge to recall state-of-charge whenever battery is disconnected.
Three possible reset methods:
Open Circuit Reset (OCR): Upon reconnection of a battery the gauge will reset if it measures 2.09 volts/ cell or higher (example “B” profile) (for units with memory option).
High Voltage Reset (HVR): Gauge must measure >2.35 volts per cell for 6 continuous minutes during charging (example “B” profile).
Charge Tracking Reset (CTR): Display tracks charge level during opportunity charging (requires gauge to be connected to battery when charging).